Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://tede.udesc.br/handle/handle/2303
Registro completo de metadados
Campo DCValorIdioma
dc.creatorMezaroba, Cristiane-
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4481566U5por
dc.contributor.advisor1Fontana, Luis Cesar-
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781604T5por
dc.contributor.advisor-co1Latteshttp://buscatextual.cnpq.br/buscatextual/busca.do#por
dc.contributor.referee1Recouvreux, Derce de Oliveira Souza-
dc.contributor.referee1Latteshttp://buscatextual.cnpq.br/buscatextual/busca.dopor
dc.contributor.referee2Nahorny, Jacimar-
dc.contributor.referee2Latteshttp://buscatextual.cnpq.br/buscatextual/busca.dopor
dc.contributor.referee3Armas, Rafael Dutra de-
dc.contributor.referee3Latteshttp://buscatextual.cnpq.br/buscatextual/busca.dopor
dc.contributor.referee4Becker, Daniela-
dc.contributor.referee4Latteshttp://buscatextual.cnpq.br/buscatextual/busca.dopor
dc.date.accessioned2017-06-09T11:56:55Z-
dc.date.issued2017-02-23-
dc.identifier.citationMezaroba, Cristiane. Esterilização por plasma do polímero PEAD através da descarga RF E N2-O2. 2017. Dissertação( Mestrado) - Universidade do Estado de Santa Catarinapor
dc.identifier.urihttp://tede.udesc.br/handle/handle/2303-
dc.description.resumoA esterilização por plasma têm oferecido vantagens em relação a outros métodos à baixa temperatura utilizados, a começar por alta eficácia e abrangente letalidade microbiana, ação rápida, compatibilidade com vários materiais, alta difusibilidade e é um sistema não poluente. O objetivo deste trabalho foi avaliar se o plasma RF indutivo (ICP) e mistura de N2-O2 é eficiente para uso em esterilização de materiais poliméricos médico-hospitalares e odontológicos, representado neste estudo pelo polímero PEAD. Também foi objetivo deste trabalho avaliar as possíveis modificações superficiais do PEAD após a esterilização. Foram utilizados filmes de PEAD com esporos de Geobacillus stearothermophilus, com ≅5,73x107 UFC/filme. Nos testes microbiológicos foram utilizadas potências de 20W e 40W, pressão de 0,5 Torr e tempos de exposição de 2,5,10,15 e 20 minutos. Foi mantida baixa temperatura (T<40°C), e os resultados demonstraram eficiência de esterilização. Os filmes de PEAD após esterilização foram caracterizados por medidas do ângulo de contato, microscopia de força atômica (AFM), microscopia eletrônica de varredura por emissão de campo (FEG-MEV) e espectroscopia no infravermelho por transformada de Fourier no modo “Refletância Total Atenuada” (FTIR-ATR). As espécies ativas formadas no plasma foram identificadas por um sistema de espectroscopia óptica de emissão (OES).por
dc.description.abstractPlasma sterilization present effective and extensive microbial lethality, fast action, compatibility with various materials, high diffusion through porous substances and are non-polluting systems. The objective of this study was to evaluate if the inductive RF plasma and N2-O2 mixture is efficient for use in sterilization of polymer medical-hospital and dental materials, represented in this study by the polymer HDPE. It was also the objective of this study to evaluate the possible superficial modifications of HDPE after sterilization. HDPE films were used with spores of Geobacillus stearothermophilus, with ≅5,73x107 UFC/film. In the microbiological tests were used 20W and 40W power, 0.5 Torr pressure and exposure times of 2,5,10,15 and 20 minutes. Low temperature was maintained (T<40°C), and the results demonstrated sterilization efficiency. The samples were characterized by contact angle measurements, atomic force microscopy (AFM), scanning electron microscopy field emission (FEG-SEM) and Fourier transform infrared spectroscopy in the "Attenuated Total Reflectance" (FTIR-ATR) mode. The active species formed in plasma were identified by a system of optical emission spectroscopy (OES).eng
dc.description.provenanceSubmitted by Ana Borges (ana.azevedo@udesc.br) on 2017-06-09T11:56:55Z No. of bitstreams: 1 Cristiane Mezaroba.pdf: 9118688 bytes, checksum: 7706a8529180fd844f20da89e3df3d57 (MD5)eng
dc.description.provenanceMade available in DSpace on 2017-06-09T11:56:55Z (GMT). No. of bitstreams: 1 Cristiane Mezaroba.pdf: 9118688 bytes, checksum: 7706a8529180fd844f20da89e3df3d57 (MD5) Previous issue date: 2017-02-23eng
dc.description.sponsorshipCAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade do Estado de Santa Catarinapor
dc.publisher.departmentCiência e Engenharia de Materiaispor
dc.publisher.countryBrasilpor
dc.publisher.initialsUDESCpor
dc.publisher.programMestrado em Ciência e Engenharia de Materiaispor
dc.relation.references"136 p." "Joinville, SC"por
dc.rightsAcesso Abertopor
dc.subjectPlasma RF ICP; N2/O2; Sterilization; bacterial spores; HDPE polymerpor
dc.subject.cnpqEngenhariaspor
dc.titleEsterilização por plasma do polímero PEAD através da descarga RF E N2-O2por
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Ciência e Engenharia de Materiais

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Cristiane Mezaroba.pdf8,9 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.